CONSTRUCTION AND BUILDING MATERIALS, cilt.400, sa.132815, ss.1-16, 2023 (SCI-Expanded)
Reinforced concrete folded plates (RC-FPs) are frequently used in structures such as industrial buildings, hangars,
swimming pools, and sports halls due to their high load-bearing capacity, low self-weight, economic advantages,
and architectural appearance. However, experimental studies on the reinforced concrete (RC) behavior of these
new-generation structural members are very limited. For this purpose, this article investigated the effect of plate
thickness and fiber hybridization on the flexural performance of V-shaped RC-FPs produced from self-compacting
concrete (SCC). With this study, the experimental moment–curvature tool was used for the first time to evaluate
the flexural performance of V-shaped RC-FP. A total of sixteen large-scale V-shaped RC-FP specimens with
different plate thicknesses (50, 60, 70, and 80 mm) and fiber hybridization (single, binary, and ternary) were
manufactured and subjected to a four-point loading after a 90-day curing period. After the experimental
load–deflection and moment–curvature curves were obtained, load-bearing capacity, toughness, curvature
ductility, and effective flexural stiffness values were calculated and also showed in the crack patterns for all
large-scale V-shaped RC-FPs. The empirical equations with high-precision have been developed using multiple
linear regression analysis for predicting the load-bearing capacity, toughness, curvature ductility, and effective
flexural stiffness of V-shaped RC-FPs based on the parameters of plate thickness and fiber hybridization.
Consequently, the use of hybrid fiber-reinforced SCC in the production of V-shaped RC-FPs exhibited superior
properties in terms of flexural performance and crack behavior, as well as allowing for accelerated erection of the
roof carrier system, resulting in significantly reducing construction time and costs. Also, fiber reinforcement
rather than an increase in plate thickness induced significant increases in the flexural performance values of the
V-shaped RC-FPs, while ternary fiber hybridization was the best.