Comparison of Intracorporeal Knot-tying Suture (Polyglactin) and Titanium Endoclips in Laparoscopic Appendiceal Stump Closure: A Prospective Randomized Study
SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, cilt.22, sa.3, ss.226-231, 2012 (SCI-Expanded, Scopus)
- Yayın Türü: Makale / Tam Makale
- Cilt numarası: 22 Sayı: 3
- Basım Tarihi: 2012
- Doi Numarası: 10.1097/sle.0b013e31824f25cd
- Dergi Adı: SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES
- Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus
- Sayfa Sayıları: ss.226-231
- Anahtar Kelimeler: laparoscopy, appendectomy, knot-tying, endoclip, OPEN APPENDECTOMY, CLINICAL-TRIAL, CHOLECYSTECTOMY, CLIP, MIGRATION, ENDOLOOPS, SECONDARY
- İnönü Üniversitesi Adresli: Evet
Özet
Background: Laparoscopic appendectomy is a well-described surgical technique. However, concerns still exist regarding whether the closure of the appendiceal stump should be done with a clip, an endoloop, staples, or other techniques. Therefore, several modifications to the original technique with new materials have been introduced for appendiceal stump closure. The aim of this study was to compare intracorporeal (polyglactin) knot-tying suture with titanium endoclips in appendiceal stump closure during laparoscopic appendectomy.