Sigma Journal of Engineering and Natural Sciences, cilt.39, sa.4, ss.331-342, 2021 (ESCI)
The aim of this study is to determine the priority areas in the meter replacement or rehabilitation
by using an integrated methodology combining the AHP and ELECTRE I methods to
reduce the non-revenue water. For this, a total of 7 criteria such as the Water Consumption
Rate, Mean Meter Age, Faulty Water Meter Ratio, Region Population Rate, Customer Loyalty
Percentage, Average Operating Pressure and Calibrated Age were considered. The AHP method
was applied to calculate the weights of the criteria and then a model based on weights of
criteria was developed using the ELECTRE I method. The model based on AHP and ELECTRE
I methods was applied by taking into account the field data records for 7 criteria and the
priority regions in water meter replacement were determined. This study will make significant
contributions in the scope of minimizing the losses caused by the meters, reducing the costs
in meter management and making the most benefit in meter replacement.