Comparison of Intracorporeal Knot-tying Suture (Polyglactin) and Titanium Endoclips in Laparoscopic Appendiceal Stump Closure: A Prospective Randomized Study


ATEŞ M., DİRİCAN A., İNCE V., ARA C., IŞIK B., YILMAZ S.

SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, vol.22, no.3, pp.226-231, 2012 (SCI-Expanded) identifier identifier identifier

  • Publication Type: Article / Article
  • Volume: 22 Issue: 3
  • Publication Date: 2012
  • Doi Number: 10.1097/sle.0b013e31824f25cd
  • Journal Name: SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES
  • Journal Indexes: Science Citation Index Expanded (SCI-EXPANDED), Scopus
  • Page Numbers: pp.226-231
  • Keywords: laparoscopy, appendectomy, knot-tying, endoclip, OPEN APPENDECTOMY, CLINICAL-TRIAL, CHOLECYSTECTOMY, CLIP, MIGRATION, ENDOLOOPS, SECONDARY
  • Inonu University Affiliated: Yes

Abstract

Background: Laparoscopic appendectomy is a well-described surgical technique. However, concerns still exist regarding whether the closure of the appendiceal stump should be done with a clip, an endoloop, staples, or other techniques. Therefore, several modifications to the original technique with new materials have been introduced for appendiceal stump closure. The aim of this study was to compare intracorporeal (polyglactin) knot-tying suture with titanium endoclips in appendiceal stump closure during laparoscopic appendectomy.